Before work starts
Once the technician has diagnosed the appliance, you hear the cost of fixing it and choose whether to proceed.
Independent appliance repair
Book a visit for a Bosch cooktop that shows dE, F2, F4, F5, U400 or E9000, or one whose zones switch off. Bosch's page lists 14 entries for induction and gas cooktops. Supply voltage messages need an electrician first.


Zones that stay cold on a Bosch induction cooktop usually trace back to one of five states: demo mode (dE), the automatic time limit (F8 with H or h), a locked panel, a damp or covered panel, or cookware the zone cannot use. Each has a quick release.

F2, F4 and F5 on a Bosch induction cooktop are heat protection, not a breakdown: electronics that run hot, or hot cookware parked near the controls, switch zones off. Let it cool, move the pan, then touch any control.
dE on a Bosch induction cooktop means demo mode is on, so the cooking zones will not heat. Switch the breaker off for 30 seconds, then touch any control on the cooktop within the next 3 minutes.
F2 on a Bosch cooktop means the electronics have overheated and the corresponding cooking zone has switched off. Wait for the electronics to cool, touch any control and carry on cooking once the message goes.
F4 on a Bosch cooktop means the electronics have overheated and all cooking zones have switched off. Wait for the electronics to cool, touch any control and continue cooking once the message disappears.
F1 on a Bosch cooktop means the cooking zone has overheated and switched off to protect the work surface. Let the electronics cool down first, and only then turn the zone on again.
F6 on a Bosch cooktop means the cooking zone has overheated and switched off to protect the work surface. Wait for the electronics to cool, then switch the zone back on and continue cooking.
U400 on a Bosch cooktop means the supply voltage is incorrect and outside the normal operating range. Contact your electrical utility provider, or book a visit once the supply has been checked.
E9000 on a Bosch cooktop means the supply voltage is incorrect and outside the normal operating range. The cooktop is not the suspect first: contact your electrical utility provider, or book a visit to have the cooktop tested.
E9010 on a Bosch cooktop is the second number on the entry for an incorrect supply voltage outside the normal operating range. Contact your electrical utility provider, then book a visit if the supply tests fine and E9010 stays.
E7010 on a Bosch cooktop means it cannot connect to your home network or to the hood. Switch the cooktop off and on again. If E7010 shows again, book a visit and note the exact code.
We raise a part only once the cooktop has been tested on site. You hear the price first and approve it before we order.

The glossary has no illustrated entry for this component yet. Lean on the system named in the explanation and the manual cited for your model; a code on its own does not point to a replacement.
Explore the researched partsFrom your request to the repair.
Tidy, and no mess left behind.

Say what you hear or see, and send the E-code if one is lit. Add the model number from the door edge.

The technician opens the dishwasher, checks the filter, pump and heater and quotes the repair before starting.

The part is fitted, a full cycle is run, and the kitchen is left as clean as it was found.
Demo mode: the zones do not heat. Bosch says to touch any control within the next 3 minutes.
The electronics overheated and the zone, or every zone, switched off. Let the cooktop cool.
Hot cookware is near the control panel. Move it away.
The supply voltage is outside the normal operating range. Switch off at the breaker and do not open the connection yourself.
U400, E9000, E9010 or E9011 shows.
F2, F4 or F5 returns after the cooktop cools.
dE stays after you touch a control.
E7010 stays: the cooktop cannot connect to the home network or hood.
Arrange a diagnosticOnce the technician has diagnosed the appliance, you hear the cost of fixing it and choose whether to proceed.
Bosch handles any repair its own warranty still covers. When we do the work, it carries our workmanship warranty.
That is demo mode. Bosch says to touch any control on the cooktop within the next 3 minutes. If it stays, book a visit.
The zone ran a long time untouched, so the automatic time limit kicked in. Bosch treats it as a mode; touch the controls to cook again.
The supply voltage is outside the normal operating range. An electrician should check it first; do not open the connection yourself.
No. It is a connection message: the cooktop cannot connect to the home network or hood.
Bosch E-codes, symptoms, parts, repair visits
dE on a Bosch induction cooktop means demo mode is on, so the cooking zones will not heat. Switch the breaker off for 30 seconds, then touch any control on the cooktop within the next 3 minutes.
Zones that stay cold on a Bosch induction cooktop usually trace back to one of five states: demo mode (dE), the automatic time limit (F8 with H or h), a locked panel, a damp or covered panel, or cookware the zone cannot use. Each has a quick release.
Arrange a diagnostic for your exact model, carried out at the appliance.
Office details, plus the access information to send us.